Kungani OFakazi BakaJehova Bengatshoni Bezihlupha Ngakho Konke Ukumangelelwa Ngabantu? OFakazi bakaJehova balandela iseluleko seBhayibhili esikhuluma ngokuthi bangabi lendaba lokunye ukumangalelwa okwenziwa ngabantu. Ngokwesibonelo, esinye isaga seBhayibhili sithi: “Lowo oweluleka oklolodayo ubiza inhlamba.”. OPERATIONAL PROGRAMME UNDER THE 'INVESTMENT FOR GROWTH AND JOBS' GOAL CCI 2014HR16M1OP001 Title Operational Programme Competitiveness and Cohesion 2014 - 2020 Version 1.2 First year 2014 Last year 2020 Eligible from 01-Jan-2014 Eligible until 31-Dec-2023 EC decision number EC decision date MS amending decision number MS amending decision date. Attestacionnaya rabota akusherki zhenskoj konsuljtacii na visshuyu kategoriyu.

• Control Module Communication.4 Carrier Comfort Network Interface.4 OPERATING DATA. • CONTENTS (cont) • LEAD/LAG DETERMINATION • CAPACITY SEQUENCE DETERMINATION • CAPACITY CONTROL OVERRIDES Head Pressure Control.27 •. • Information is transmitted between modules via a 3-wire com- UNIT 30GTN,R munication bus or LEN (Local Equipment Network).

Find the cheap Carrier Air Conditioner Manual, Find the best Carrier Air. Remote control for Air Conditioner, Carrier-RFL-0601E, RFL-0601EH, RFL-0601EL.

The — — CCN (Carrier Comfort Network) bus is also supported. Con- — nections to both LEN and CCN buses are made at TB3. • YELLOW LED — The MBB has one yellow LED. The Carrier Comfort Network (CCN) LED will blink during times of network communication. Carrier Comfort Network (CCN) Interface — The 30GTN,R chiller units can be connected to the CCN if desired.

• CR-A1 CR-A1 CR-A1 LEGEND FOR FIG. 1-4 — Compressor Contactor — Circuit Breaker — Carrier Comfort Network — Compressor Ground Fault — Cooler Heater Thermostat — Circuit — Cooler Heater Relay — Compressor Protection and Control System — Chilled Water Flow Switch —. • DATA COMMUNICATION PORT Fig. 2 — 24 V Control Schematic, Unit Sizes 040-070. • DATA COMMUNICATION PORT Fig.

3 — 24 V Control Schematic, Unit Sizes 080-110, 230B-315B Fig. 3 — 24 V Control Schematic, Unit Sizes 080-110, 230B-315B. • DATA COMMUNICATION PORT Fig. 4 — 24 V Control Schematic, Unit Sizes 130-210, 230A-315A, 330A/B-420A/B. • LEN (LOCAL EQUIPMENT NETWORK) CEPL130346-01 STATUS Fig. 6 — Enable/Off/Remote Contact Switch, Emergency On/Off Switch, YELLOW LED - CCN (CARRIER COMFORT NETWORK) Fig.

5 — Main Base Board RESET BUTTON (SIZES 130-210 AND ASSOCIATED MODULES ONLY) and Reset Button Locations. • OPERATING DATA Sensors — The electronic control uses 4 to 10 thermistors to sense temperatures for controlling chiller operation. These sensors are outlined below. 7-10 for thermistor locations. Thermistors T1-T9 are 5 kΩ at 77 F (25 C). • 040-070 080-110 AND ASSOCIATED MODULAR UNITS* 130-210 AND ASSOCIATED MODULAR UNITS* *When thermistor is viewed from perspective where the compressor is on the left and the cooler is on the right. 8 — Thermistor T3 and T4 Locations.

• LEGEND EXV — Electronic Expansion Valve Fig. 9 — Compressor Thermistor Locations (T7 and T8) Fig. 10 — Typical Thermistor Location (30GTN,R and 30GUN,R 210, 315A, 390A, 420A/B Shown) • The space temperature sensor includes a terminal block (SEN) and a RJ11 female con- nector. The RJ11 connector is used to tap into the Carrier Com- fort Network (CCN) at the sensor. To connect the space temperature sensor (Fig. • Thermostatic Expansion Valves (TXV) — 30GTN,R and 30GUN,R 040-110 units are available from the factory with conventional TXVs with liquid line solenoids.

The liquid line solenoid valves are not intended to be a mechanical shut-off. When service is required, use the liquid line service valve to pump down the system. • Electronic Expansion Valve Fig. 15) — Standard units are equipped with a bottom seal EXV.

This device eliminates the use of the liquid line solenoid pumpdown at unit shutdown. An O-ring has been added to bot- tom of orifice assembly to complete a seal in the valve on shut- down. • CEBD4-01C STATUS RED LED - STATUS The capacity control algorithm runs every 30 seconds.

The algorithm attempts to maintain the leaving chilled water tem- perature at the control point. Each time it runs, the control reads the entering and leaving fluid temperatures. The control deter- mines the rate at which conditions are changing and calculates 2 variables based on these conditions. • Table 5A — Part Load Data Percent Displacement, Standard Units UNIT CONTROL 30GTN,R STEPS 30GUN,R 040 (60 Hz) 040 (50 Hz) 045 (60 Hz) 045 (50 Hz) 050 (60 Hz) 050 (50 Hz) 060 (60 Hz) 060 (50 Hz) 070 (60 Hz) 070 (50 Hz) 080, 230B (60 Hz) 080, 230B (50 Hz) • Table 5A — Part Load Data Percent Displacement, Standard Units (cont) UNIT CONTROL 30GTN,R STEPS 30GUN,R 100, 255B 270B (50 Hz) 110, 290B, 315B (60 Hz) 110, 290B, 315B (50 Hz) 130 (60 Hz) 130 (50 Hz) 150, 230A, 245A, 255A (60 Hz) *Unloaded compressor.